Commit 5aaf3dfd authored by Médéric Boquien's avatar Médéric Boquien

Add pseudo filters to measure Halpha, Hbeta, and OIII. Beware that the fluxes...

Add pseudo filters to measure Halpha, Hbeta, and OIII. Beware that the fluxes will be affected by any underlying absorption line. Also make sure that the continuum part of the filter is not significantly affected by emission lines. It is recommended to adapt the filter depending on the actual resolution of the spectral observations.
parent 8ae3ba4c
# linefilter.H-alpha-100
# energy
# H-alpha pseudo filter, R=100. The flux will not be corrected for any absorption line. Make sure the continuum part is not affected by emission lines. Feel free to adapt the filter if the resolution is not adequate.
6497.370000 -1.0
6530.185000 -1.0
6530.185001 1.0
6595.814999 1.0
6595.815000 -1.0
6628.630000 -1.0
# linefilter.H-alpha-50
# energy
# H-alpha pseudo filter, R=50. The flux will not be corrected for any absorption line. Make sure the continuum part is not affected by emission lines. Feel free to adapt the filter if the resolution is not adequate.
6431.740000 -1.0
6497.370000 -1.0
6497.370001 1.0
6628.629999 1.0
6628.630000 -1.0
6694.260000 -1.0
# linefilter.H-alpha-75
# energy
# H-alpha pseudo filter, R=75. The flux will not be corrected for any absorption line. Make sure the continuum part is not affected by emission lines. Feel free to adapt the filter if the resolution is not adequate.
6475.493333 -1.0
6519.246667 -1.0
6519.246668 1.0
6606.753332 1.0
6606.753333 -1.0
6650.506667 -1.0
# linefilter.H-beta-100
# energy
# H-beta pseudo filter, R=100. The flux will not be corrected for any absorption line. Make sure the continuum part is not affected by emission lines. Feel free to adapt the filter if the resolution is not adequate.
4812.390000 -1.0
4836.695000 -1.0
4836.695001 1.0
4885.304999 1.0
4885.305000 -1.0
4909.610000 -1.0
# linefilter.H-beta-125
# energy
# H-beta pseudo filter, R=125. The flux will not be corrected for any absorption line. Make sure the continuum part is not affected by emission lines. Feel free to adapt the filter if the resolution is not adequate.
4822.112000 -1.0
4841.556000 -1.0
4841.556001 1.0
4880.443999 1.0
4880.444000 -1.0
4899.888000 -1.0
# linefilter.H-beta-75
# energy
# H-beta pseudo filter, R=75. The flux will not be corrected for any absorption line. Make sure the continuum part is not affected by emission lines. Feel free to adapt the filter if the resolution is not adequate.
4796.186667 -1.0
4828.593333 -1.0
4828.593334 1.0
4893.406666 1.0
4893.406667 -1.0
4925.813333 -1.0
# linefilter.OIII-50
# energy
# OIII pseudo filter, R=50. The flux will not be corrected for any absorption line. Make sure the continuum part is not affected by emission lines. Feel free to adapt the filter if the resolution is not adequate.
4883.340000 -1.0
4933.170000 -1.0
4933.170001 1.0
5032.829999 1.0
5032.830000 -1.0
5082.660000 -1.0
# linefilter.OIII-75
# energy
# OIII pseudo filter, R=75. The flux will not be corrected for any absorption line. Make sure the continuum part is not affected by emission lines. Feel free to adapt the filter if the resolution is not adequate.
4916.560000 -1.0
4949.780000 -1.0
4949.780001 1.0
5016.219999 1.0
5016.220000 -1.0
5049.440000 -1.0
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!